CS/DS Essentials: the 13 measures every HIA entity must put in place
MOH’s Cybersecurity and Data Security (CS/DS) Essentials set out the security measures for storing, accessing, using and sharing health information.
Source 4 of 4 · PDPA Compliance team · Last checked 21 November 2026
Source
MOH Cybersecurity and Data Security Essentials
Edition
First edition, March 2026
Applies to
All HCSA licensees, NEHR contributors and users, and prescribed entities that share health information
The 13 measures
A. Cybersecurity: IT and software
1
UpdateInstall software updates promptly, critical and important ones first.
2
Secure and protectAnti-malware, firewalls, access controls and secure settings on hardware and software.
3
BackupBack up essential data regularly, stored apart from the systems in use.
4
AssetsAuthorise, list and protect hardware and software; replace unauthorised or unsupported items.
B. Data security
5
SecureKnow where health information is held, protect it, keep copies to what is needed and transfer it safely.
6
IdentifyMark health information so staff recognise it and handle it properly.
7
AccessGive access only to staff with a real need who have acknowledged the security measures.
C. Common practices
8
TrainingRegular security awareness training, ideally at least once a year.
9
VendorsKnow each vendor’s security duties, where data is stored and its incident duties in the contract.
10
Reviews and internal auditReview safeguards and compliance from time to time, and fix lapses promptly.
11
DisposalDestroy health information securely before disposing of data or hardware.
12
Contingency planningKeep a business continuity plan for cyber incidents and disruptions.
13
Incident responseKeep an up-to-date incident response plan, known to the staff who need it.
Reporting an incident
Step
Deadline
Initial notification to MOH
Within 2 hours after assessing that the incident is notifiable
Incident report to MOH
Within 14 days of the initial notification
Notify affected individuals
At the same time as, or as soon as practicable after, notifying MOH, where significant harm is caused or likely
A data breach is notifiable if it causes, or is likely to cause, significant harm to an individual, or is of significant scale: 500 or more people affected. MOH states that the HIA reporting requirements have not yet taken effect, and that it will announce when they start.
Where the measures apply
The cybersecurity measures apply to computers that contain health information or connect to the NEHR.
The data security measures apply to both electronic and paper records.
A clinic system certified under Cyber Essentials already builds in some controls. Your other IT still has to meet the requirements.